QL124-20-2460|Measuring Light Curtain Sensor|DADISICK
QL124-20-2460|Measuring Light Curtain Sensor|DADISICK
QL124-20-2460|Measuring Light Curtain Sensor|DADISICK
QL124-20-2460|Measuring Light Curtain Sensor|DADISICK
QL124-20-2460|Measuring Light Curtain Sensor|DADISICK
QL124-20-2460|Measuring Light Curtain Sensor|DADISICK
Model
QL124-20-2460

Item specifics

Factory packaging
1 Receiver and 1Emitter accessories, cable
Detection distance:
0.3-6M
Beam spacing:
20mm
Number of optical axes:
124
Protection height:
2460mm
Output mode
RS485/RS232, I: 4-20mA, U: 1-10V
Interface plug
Equipped with M12 connector
Certification:
TUV,UL,CE,RoSH,GB

Review

Description

Product model
Products series
QL Measuring Light Curtain Sensor
Punch press guarding kit composition
One receiver, one transmitter, two data lines, one right-angle rack, and one t-shaped screw
Application
Infrared radiation type
Standard packaging
Standard industrial environment
Features
Beam gap
20mm
Detect accuracy
25mm
Quantity of beams
124
Operation range
2460mm
Product size
36mm*36mm*L,L is the length of emitter and receiver.
Detection distance
30-6000mm
Response time
≤15ms
Mechanical data
Housing material
Housing material
Metal casing
Aluminium
Lens front panel
Acrylic
Upper and lower cap materials
ABS reinforced nylon PA66+30% GF
Synchronization
Current consumption
≤200mA
Output mode
2  PNP, with current of 500mA and voltage below 1.5V, polarity, short circuit and over-cutting protection
Output status
ON (receiving indicator green light)
Indicator lamp
Transmitter: power indicator light (red); receiver: output indicator light on (green), blackout (red)
Wave length
850nm
Type of emitter
Infrared light (NIR), invisible
Function available
Automatic reset
Synchronization
Line synchronization
Performance data
Circuit protection
Short circuit protection
Voltage protection
Overvoltage protection
Maximum current consumption
24VDC,-20...20%
Fuse
150mA
Environmental data
IP degree of protection
IP65
Resistance to ambient light disturbance
Incandescent light: illumination of light-receiving surface 3000Lx; Sunlight: illumination of light-receiving surface 10000Lx
Ambient air temperature
Operation temperature: - 10~+40 ℃ (but not frozen), storage temperature: - 25 -+55 ℃
Ambient relative humidity
Operating: 35~85% RH, storage: 35~95% RH
Output
Number of safe output circuits (OSSD)
1-circuit
Maximum switch voltage
18V
Minimum switch voltage
2.5V
Standard switching voltage
22.5V
Output circuit type
DC
Maximum current load
380mA
Load inductance
2000
Load capacity
0.3
Maximum residual current
0.2mA
Standard residual current
0.002MA
Voltage drop
1.5V
Safety output 
Connection pin 4, WHITE OSSD NPN/PNP
Communication protocol
Connection pin 5, RED RS485A;Connection pin 6, GREEN RS485B
Electrical interface
Composition of interfaces
2 (Receiver and Emitter)
Connector type
M12 connector
Interface material
Copper nickel plating
Plug material
GY384 gray 30P
Available typical conductor section
0.25mm²
Maximum lenght of cable
100m
Maximum load of cable
4.9A
Cable wrapping material
PVC
DIMENSION                                                                                                                                                                                           
Safety Light Curtain Dimension
ACCESSORIES                                                                                                                                                                                           
Safety light curtain QM series accessories for QLMR-06 Top and bottom brackets
Reliable installation for light curtain, quick and easy adjustment, strong design, suitable for harsh industrial environment
Safety light curtain  QM series  accessories for QCA-02  T-shaped card slot
It can be directly put into the aluminum groove, in the process of installation, it can automatically locate and lock.
Safety light curtain QM series accessories for QCA-03 Convex groove
convex nut feature: high production efficiency, good heat dissipation, easy to use and maintenance.
Controller QET
Controller QET for Dadisick Safety Light Curtains
DOCUMENTS & DOWNLOADS                                                                                                                                                                                          
CATALOGUE & USER GUIDE

Measuring Light Barrier Curtains QL Series-data sheet

Measuring Light Barrier Curtains QL Series User Manual

3D
QL124-20-2460.3D-STEP
CERTIFICATE
TUV Certificate of Safety Light Curtain
UL Certificate of Safety Light Curtain
RoHS Certificate of Safety Light Curtain
ISO Certificate of Safety Light Curtain
CE Certificate of Safety Light Curtain
DIMENSIONED DRAWINGS                                                                                                                                                                                         
Cable Description
Safety Light Curtain Cable Description
RS485 Output Wiring Diagram
Safety Light Curtain RS485 Output Wiring Diagram
analog U/I wiring diagram
Measuring Light Barrier Curtains Analog U/I Wiring Diagram