OX-H1 | Non-contact Safety Door Switch | DADISICK
- Model
- OX-H1 | OX-H1-FN-S-□ ,OX-H1-FN-D-□,OX-H1-FP-S-□,ОX-H1-FP-D-□,OX-H1-EN-S-□,OX-H1-EN-D-□,OX-H1-EP-S-□,OX-H1-EP-D-□
Item specifics
- Output type:
- NPN,PNP
- Cascade:
- Cascading is not supported,Support cascade
- Operating voltage:
- 24 V DC
- Response time:
- 60 ms
Review
Description
Performance Specifications
|
||||
Universal coding type | OX-H1-FN-S-□ | OX-H1-FP-S-□ | OX-H1-EN-S-□ | OX-H1-EP-S-□ |
Unique encoding type | OX-H1-FN-D-□ | ОX-H1-FP-D-□ | OX-H1-EN-D-□ | OX-H1-EP-D□ |
Output type | NPN | PNP | NPN | PNP |
Cascade | Cascading is not supported | Support cascade | ||
Horizontal conduction distance
|
0-10 mm |
|||
Horizontal break distance
|
>25 mm |
|||
Vertical conduction distance
|
0-6 mm |
|||
Vertical break distance
|
>15 mm |
|||
Repeatability | 0.5 mm | |||
Operating voltage | 24 V DC | |||
Working current | 30 mA | |||
Safe output current | 150 mA | |||
Auxiliary output current | 50 mA | |||
Response time | 60 ms | |||
Protection level | IP67(EN60947-5-1) | |||
Coding level | Universal encoding:Low level coded (ISO 14119) | |||
Unique code:High level coded (ISO 14119) | ||||
Interlocking type | Type 4(ISO14119) | |||
Operating frequency | 1 Hz | |||
Operating temperature | -10 C° ~ +55 C° | |||
Relative humidity | 5% - 95% | |||
Material | Thermoplastic PBT | |||
Cascade | Support cascade model optional | |||
Diagnostic output | Support | |||
Connection method | Direct outlet, cable length 3 meters |