Non-contact Safety Door Switch OX-R1 Series | RFID Technology
Non-contact Safety Door Switch OX-R1 Series | RFID Technology
Non-contact Safety Door Switch OX-R1 Series | RFID Technology
Non-contact Safety Door Switch OX-R1 Series | RFID Technology
Model
OX-R1 Series | OX-R1-FN-S-P1, OX-R1-FP-S-P1, OX-R1-EN-S-P1, OX-R1-EP-S-P1, OX-R1-FN-D-P1, OX-R1-FP-D-P1, OX-R1-EN-D-P1, OX-R1-EP-D-P1

Item specifics

Cascade type:
Support cascade or Do not support cascade
Output type:
Dual NPN output or Dual PNP output
Coding type:
Universal code or Unique code
Horizontal distance:
Conduction, min: 10 mm
Vertial distance:
Conduction, min: 8 mm

Review

Description

Model Speciǁcations
Safety standards
ISO13849-1, IEC/EN60947-5-1, IEC/EN60947-5-3
Safety classiǁcation
Class 4 switch with IS0 13849-1/suitable for PLe/PLd
Certification
CE
Horizontal distance
Conduction, min: 10 mm
Vertical distance
Conduction, min: 8 mm
Operating voltage
24 V DC±15%
Operating current
30 mA
Output current
150 mA
Response time
60 ms
Protection level
IP65, IP67 (customized)\IP68 (customized)
Operating frequency
1 Hz
Operating temperature
-10 ~ +55°C
Relative humidity
5 ~ 95%
Material
Anti-flame retardant thermoplastic
Model Description
Model
Speciǁcations
OX-R1-FN-S-P1
4-core direct wiring dual NPN output 2M line
OX-R1-FP-S-P1
4-core direct wiring dual PNP output 2M line
OX-R1-EN-S-P1
6-core direct wiring dual NPN output with cascade 2M line
OX-R1-EP-S-P1
6-core direct wiring dual PNP output with cascade 2M line
OX-R1-FN-D-P1
4-core direct wiring dual NPN output 2M line, Actuator with unique code
OX-R1-FP-D-P1
4-core direct wiring dual PNP output 2M line, Actuator with unique code
OX-R1-EN-D-P1
6-core direct wiring dual NPN output with cascade 2M line, Actuator with unique code
OX-R1-EP-D-P1
6-core direct wiring dual PNP output with cascade 2M line, Actuator with unique code
Indicator Status
Led Display
Signal Status
Status Description
Input
Output
Red light always on
Yes/No
Disconnect
No actuator or not fully aligned (universal encoding)
Red light on for 1 second and then flashes 2 times (alternatingly)
Yes/No
Disconnect
No actuator or not fully aligned (unique encoding)
Red light flashes at 4 Hz
Yes
Disconnect
Output overload
Green light flashes at 1 Hz
No
Disconnect
No input signal (dual output not applicable)
Green light always on
Yes
Connect
Sensing normal
Red and green lights flash alternately
Yes
Disconnect
Tag not registered
Dimensions
Dimensions  (unit: mm)

Non-contact Safety Door Switch dimensions
Switch approach direction diagram
Safety Switch approach direction diagram
Wiring Method
Dual-channel dual-output wiring diagram
Non-contact Safety Switch Dual-channel dual-output wiring diagram
Dual-channel cascade connection diagram
Non-contact Safety Door Switch Dual-channel cascade connection diagram
Example of dual NPN output with cascade connection
RFID Safety Switches Example of dual NPN output with cascade connection
Example of dual PNP output with cascade wiring
RFID Safety Switches Example of dual PNP output with cascade wiring