Capacitive Proximity Sensor | Water Pressure Cylindrical M30 POM M12 Connector CR30 Connector Shielded | DADISICK
- Model
- Standard Capacitive Proximity Sensor | CR30 Connector Shielded | CR30-20NO-YAA-TA-MR, CR30-20NC-YAA-TA-MR, CR30-20PO-YAA-TA-MR, CR30-20PC-YAA-TA-MR, CR30-20PS-YAA-TA-MR, CR30-20NS-YAA-TA-MR
Item specifics
- Size:
- Cylindrical M30
- Detection range:
- 2-20mm Adjustable
- Case material:
- POM
- Connection type:
- M12 Connector
- Output method:
- NPN NO/NC, PNP NO/NC
- Degree of protection:
- IP67
- Operating temperature:
- -25°C~+70°C
Review
Description
Standard Capacitive Proximity Sensor Water Pressure Cylindrical M30 Connector Shielded Series Datasheet
|
||||||||
Model
|
Output | Sensing distance | Connection | Maximum load current | Mounting | Operating voltage | Case material |
|
CR30-20NO-YAA-TA-MR
| NPN NO | 2-20mm Adjustable | M12 Connector | 200mA | Shielded | 10-30VDC | POM | |
CR30-20NC-YAA-TA-MR | NPN NC | |||||||
CR30-20PO-YAA-TA-MR
| PNP NO | |||||||
CR30-20PC-YAA-TA-MR
| PNP NC | |||||||
CR30-20PS-YAA-TA-MR | PNP NO&NC | |||||||
CR30-20NS-YAA-TA-MR | NPN NO&NC |
Electrical data
|
|||
LED Display
|
Yes
|
||
Allowable ripple voltage
|
<10%
|
||
No-load current
|
<10mA
|
||
Leakage Current | <0.01mA | ||
Voltage drop | <2.0VDC | ||
Switching frequency
| 100HZ | ||
Response time | 1.5ms | ||
Switching Hysteresis | <15%(Sr) | ||
Repeat accuracy | <5%(Sr) | ||
Degree of protection | IP67 | ||
Operating temperature | -25℃ to +70℃ | ||
Temperature Drift | <10%(Sr) | ||
Load short-circuit protection / reverse polarity protection | Yes | ||
Overload protection | 220mA | ||
Sensing surface material | PBT |