Pilz PNOZ X2.8P Safety Relay Configuration

Pilz PNOZ X2.8P Safety Relay Configuration

Summary

Pilz PNOZ X2.8P safety relays are widely used in industrial safety control scenarios such as light curtains and emergency stop buttons. They have features such as forced-guided relays, LED status indicators, and standardized wiring methods, and are suitable for the protection needs of automation equipment with high safety levels.

Pilz PNOZ X2.8P Safety Relay Configuration
PNOZ X2.8P is a popular safety relay product from Pilz with a high cost-effectiveness. It belongs to the PNOZ X series. It is easy to configure, can quickly realize multiple functions, is equipped with spring-loaded or screw-type connections to support fast installation, and has compact size. It is suitable for emergency stop, safety door, and light curtain safety circuit scenarios.

PNOZ X series product introduction

Product Name
Description
Two-hand monitoring
The two-hand monitors PNOZ X ensure safe monitoring of two-hand pushbuttons in categories IIC and IIIA (according to EN 574).
To monitor emergency stops, safety gates, light barriers
The safety relays PNOZ X monitor emergency stop buttons, safety gates, light barriers, light grids, light curtains and limit switches.
Pressure sensitive mat monitoring
Ideal for monitoring safety edges and safety mats
Muting controller
Muting controller for suspending safety functions (muting)
Standstill and voltage monitoring
For safe monitoring of standstill or voltage
Time monitoring
PNOZ X safety relays can monitor emergency stops, safety doors, light barriers, and have a delayed power-off function. Some units can be used as safety timing relays with functions such as pulse timing.
Next, we will briefly introduce the parameter settings of the PNOZ X.8P safety relay.
Pilz PNOZ X safety relays

Basic description of LED indicator function

Text description
State
Functional Description
PWR
Always on
Power status indicator
CH.1
Always on
Input circuit of channel S12 is closed
CH.2
Always on
Input circuit of channel S22 is closed

Terminal Function Description

Terminal Function Description
Terminal number
Functional Description
A1、A2
power supply
S11、S52
Safety input channel 1
S21、S22 
Safety input channel 2
S12、S34
Startup circuit (reset mode)
13、14
Safety contacts
23、24
Safety contacts
33、34
Safety contacts
41、42
Auxiliary contacts
The terminal arrangement can refer to the figure above.

Specific description: 


Single channel operation

Input circuit has no redundant design a

nd can detect ground faults in the start-up circuit and input circuit.

Dual-channel operation

1. Short circuit detection between contacts (selectable according to actual situation)
2. Redundant input circuit is adopted to detect ground fault of start circuit and input circuit, as well as short circuit of input circuit and monitored start circuit.
3. Short circuit detection between contacts with short circuit detection between contacts: Based on the above functions, a short circuit detection function between the input circuit contacts has been added.

Startup mode

1. Automatic start: When the input circuit is closed, the unit is directly activated.
2. Manual start: The unit is activated only when the input circuit and the start circuit are closed at the same time.