Ring Inductive Proximity Sensor | Time-delay Dynamic Mode | LI03, LI04, LI05, LI06, LI08 Pre-wired and Connector Inner Hole DiameterInner 3, 4, 5, 6, 8mm | DADISICK
- Model
- Ring Inductive Proximity Sensor | LI03, LI04, LI05, LI06, LI08 Pre-wired and Connector | LI03-20NS-ZBA-4A-PN, LI03-20PS-ZBA-4A-PN, LI03-20PS-YBA-TA-PN, LI03-20NS-YBA-TA-PN, LI04-20NS-ZBA-4A-PN, LI04-20PS-ZBA-4A-PN, LI04-20NS-YBA-TA-PN, LI04-20PS-YBA-TA-PN, LI05-20NS-ZBA-4A-PN, LI05-20PS-ZBA-4A-PN, LI05-20NS-YBA-TA-PN, LI05-20PS-YBA-TA-PN, LI06-20NS-ZBA-4A-PN, LI06-20PS-ZBA-4A-PN, LI06-20NS-YBA-TA-PN, LI06-20PS-YBA-TA-PN, LI08-20NS-ZBA-4A-PN, LI08-20PS-ZBA-4A-PN, LI08-20NS-YBA-TA-PN, LI08-20PS-YBA-TA-PN
Item specifics
- Inner Hole DiameterInner:
- 3, 4, 5, 6, 8mm
- Detection range:
- 20mm
- Case material:
- PBT
- Connection type:
- 2M Cable, M12 Connector
- Output method:
- NPN NO/NC,PNP NO/NC
- Degree of protection:
- IP67
- Operating temperature:
- -25°C~+70°C (248~343K)
Review
Description
Ring Inductive Proximity Sensor Time-delay Dynamic Mode Pre-wired and Connector Series Datasheet |
|||||||||||
Model |
Output | Connection | Inner hole diameter | Sensing distance | Maximum load current | Mounting | Operating voltage | Case material |
|||
LI03 Pre-wired | LI03-20NS-ZBA-4A-PN | NPN NO+NC | 2 M cable | 3mm | 20mm | 200mA | Non-shielded | 10-30VDC | PBT | ||
LI03-20PS-ZBA-4A-PN
| PNP NO+NC | ||||||||||
LI03 Connector | LI03-20NS-YBA-TA-PN
| NPN NO+NC | M12 connector | ||||||||
LI03-20PS-YBA-TA-PN
| PNP NO+NC |
LI04 Pre-wired | LI04-20NS-ZBA-4A-PN | NPN NO+NC | 2 M cable | 4mm | 20mm | 200mA | Non-shielded | 10-30VDC | PBT | ||
LI04-20PS-ZBA-4A-PN
| PNP NO+NC | ||||||||||
LI04 Connector | LI04-20NS-YBA-TA-PN
| NPN NO+NC | M12 connector | ||||||||
LI04-20PS-YBA-TA-PN
| PNP NO+NC |
LI05 Pre-wired | LI05-20NS-ZBA-4A-PN | NPN NO+NC | 2 M cable | 5mm | 20mm | 200mA | Non-shielded | 10-30VDC | PBT | ||
LI05-20PS-ZBA-4A-PN
| PNP NO+NC | ||||||||||
LI05 Connector | LI05-20NS-YBA-TA-PN
| NPN NO+NC | M12 connector | ||||||||
LI05-20PS-YBA-TA-PN
| PNP NO+NC |
LI06 Pre-wired | LI06-20NS-ZBA-4A-PN | NPN NO+NC | 2 M cable | 6mm | 20mm | 200mA | Non-shielded | 10-30VDC | PBT | ||
LI06-20PS-ZBA-4A-PN
| PNP NO+NC | ||||||||||
LI06 Connector | LI06-20NS-YBA-TA-PN
| NPN NO+NC | M12 connector | ||||||||
LI06-20PS-YBA-TA-PN
| PNP NO+NC |
LI08 Pre-wired | LI08-20NS-ZBA-4A-PN | NPN NO+NC | 2 M cable | 8mm | 20mm | 200mA | Non-shielded | 10-30VDC | PBT | ||
LI08-20PS-ZBA-4A-PN
| PNP NO+NC | ||||||||||
LI08 Connector | LI08-20NS-YBA-TA-PN
| NPN NO+NC | M12 connector | ||||||||
LI08-20PS-YBA-TA-PN
| PNP NO+NC |
Electrical data
|
|||||
LED display
|
Yes
|
||||
Allowable ripple voltage
|
<10%
|
||||
Minimum interval time of the object to be detected | 0.1ms | ||||
No-load current
|
<10mA
|
||||
Leakage current | <0.01mA | ||||
Adjustable pulse width time
| 0.1-200ms
| ||||
Response time | 0.1ms | ||||
Voltage drop | <1.5v at 200mA | ||||
Switching frequency | 2KHZ | ||||
Adjustable sensitivity | Yes | ||||
Switching hysteresis | 15% | ||||
Repeat accuracy | <2%(Sr) | ||||
Degree of protection | IP67 | ||||
Operating temperature | -25℃ to +70℃ | ||||
Temperature drift | ±10%(Sr) | ||||
Minimum detection object | Steel ball diameter 1mm (Inner hole diameter 3mm, 4mm), Steel ball diameter 1.5mm (Inner hole diameter 5mm), Steel ball diameter 2mm (Inner hole diameter 6mm), Steel ball diameter 2.5mm (Inner hole diameter 8mm) | ||||
Fastest passing speed
| 40m/s | ||||
Load short-circuit protection / reverse polarity protection | Yes | ||||
Overload protection | 220mA |
Data sheet