DK-GF18 Series DC Retro-reflective Photoelectric Sensors
- Model
- DK-GF18 Series / DC Retro (6 models)
Item specifics
- Series
- DK-GF18 Series
- Specification group
- DC 3-wire / 4-wire Retro-reflection
- Part numbers in group
- 6
- Sensing distance
- 30-4000 mm adjustable
- Light source
- 940 nm infrared
- Operating voltage
- 10-30 V DC
- Output options
- NPN / PNP, NO / NC / NO+NC
- Protection level
- IP55
- Housing
- 50 x 50 x 18 mm, ABS
- Response time
- 5 ms
- Connection
- Ø6.5 mm 2 m PVC cable
- Weight
- About 97 g + 10 g reflective board
- Certification
- CE, RoHS
Review
Description
DADISICK · DK-GF18 Series · Group B DC 3-wire and 4-wire retro-reflective sensors with an adjustable 30-4000 mm sensing distance. 6 orderable part numbers covering NPN and PNP outputs in NO, NC and NO+NC configurations. A reflective board is supplied. This group contains 6 orderable part number(s). Choose the output type and sensing distance you need, then quote the exact part number from the table below. Output codes: NO / NC / NS = NPN NO / NC / NO+NC; PO / PC / PS = PNP NO / NC / NO+NC; J = relay output. 3-wire models use one switched output, 4-wire models provide NO + NC, and relay models provide NO + NC contacts. Confirm the wiring against the label of the unit received before energising. Do not connect the output to a load exceeding the rated current. Tell us the exact part number from the model table, the target object and distance, your supply voltage, and the quantity. Our engineers will confirm the configuration and send a quotation. This is a general-purpose photoelectric sensor for object detection; it is not a safety-rated device and must not be used for personnel protection.DC Retro-reflective Photoelectric Sensors
Get a Quote
Orderable models in this group
Part number
Output
Wires
Sensing distance
DK-GF18-400NO-ZCA
NPN NO
3-wire
30-4000 mm
DK-GF18-400NC-ZCA
NPN NC
3-wire
30-4000 mm
DK-GF18-400PO-ZCA
PNP NO
3-wire
30-4000 mm
DK-GF18-400PC-ZCA
PNP NC
3-wire
30-4000 mm
DK-GF18-400NS-ZCA
NPN NO + NC
4-wire
30-4000 mm
DK-GF18-400PS-ZCA
PNP NO + NC
4-wire
30-4000 mm
Technical parameters
Parameter
Value
Sensing distance
30-4000 mm, adjustable
Light source
940 nm infrared light
Standard detection object
200 x 200 mm white cardboard
Output options
DC 3-wire / 4-wire NPN or PNP, NO / NC / NO+NC
Operating voltage
10-30 V DC
No-load current
<15 mA
Maximum load current
150 mA
Leakage current
<0.01 mA
Voltage drop
<1.5 V
Switching frequency
100 Hz
Response time
5 ms
Short-circuit protection
Yes
Overload protection point
300 mA
Switching hysteresis
<15% (Sr)
Repeat accuracy
<5% (Sr)
Protection level
IP55
Working temperature
0 °C to +55 °C
Connection method
Ø6.5 mm 2 m PVC cable, 3x0.33 mm² (3-wire) / 4x0.33 mm² (4-wire)
Housing
50 x 50 x 18 mm, ABS
Indicator
Red LED
Weight
About 97 g + 10 g reflective board
Certification
CE, RoHS
Dimensions
Wiring
Wire colour
Function
Brown (1)
+10-30 V DC
Blue (3)
0 V
Black (2 / 4)
Switched output to load
White (2)
Second switched output on 4-wire models
Request a quote for this specification group