DK-GF18 Series DC Retro-reflective Photoelectric Sensors
DK-GF18 Series DC Retro-reflective Photoelectric Sensors
DK-GF18 Series DC Retro-reflective Photoelectric Sensors
DK-GF18 Series DC Retro-reflective Photoelectric Sensors
DK-GF18 Series DC Retro-reflective Photoelectric Sensors
DK-GF18 Series DC Retro-reflective Photoelectric Sensors
Model
DK-GF18 Series / DC Retro (6 models)

Item specifics

Series
DK-GF18 Series
Specification group
DC 3-wire / 4-wire Retro-reflection
Part numbers in group
6
Sensing distance
30-4000 mm adjustable
Light source
940 nm infrared
Operating voltage
10-30 V DC
Output options
NPN / PNP, NO / NC / NO+NC
Protection level
IP55
Housing
50 x 50 x 18 mm, ABS
Response time
5 ms
Connection
Ø6.5 mm 2 m PVC cable
Weight
About 97 g + 10 g reflective board
Certification
CE, RoHS

Review

Description

DADISICK · DK-GF18 Series · Group B

DC Retro-reflective Photoelectric Sensors

DC 3-wire and 4-wire retro-reflective sensors with an adjustable 30-4000 mm sensing distance. 6 orderable part numbers covering NPN and PNP outputs in NO, NC and NO+NC configurations. A reflective board is supplied.

  • 6 part numbers
  • 30-4000 mm
  • 10-30 V DC
  • NPN / PNP
  • IP55
  • Reflector included
Get a Quote
DK-GF18 series DC retro-reflective photoelectric sensor with reflective board
Retro-reflective versions are supplied with a reflective board.

Orderable models in this group

This group contains 6 orderable part number(s). Choose the output type and sensing distance you need, then quote the exact part number from the table below.

Part number Output Wires Sensing distance
DK-GF18-400NO-ZCA NPN NO 3-wire 30-4000 mm
DK-GF18-400NC-ZCA NPN NC 3-wire 30-4000 mm
DK-GF18-400PO-ZCA PNP NO 3-wire 30-4000 mm
DK-GF18-400PC-ZCA PNP NC 3-wire 30-4000 mm
DK-GF18-400NS-ZCA NPN NO + NC 4-wire 30-4000 mm
DK-GF18-400PS-ZCA PNP NO + NC 4-wire 30-4000 mm

Output codes: NO / NC / NS = NPN NO / NC / NO+NC; PO / PC / PS = PNP NO / NC / NO+NC; J = relay output. 3-wire models use one switched output, 4-wire models provide NO + NC, and relay models provide NO + NC contacts.

Technical parameters

Parameter Value
Sensing distance 30-4000 mm, adjustable
Light source 940 nm infrared light
Standard detection object 200 x 200 mm white cardboard
Output options DC 3-wire / 4-wire NPN or PNP, NO / NC / NO+NC
Operating voltage 10-30 V DC
No-load current <15 mA
Maximum load current 150 mA
Leakage current <0.01 mA
Voltage drop <1.5 V
Switching frequency 100 Hz
Response time 5 ms
Short-circuit protection Yes
Overload protection point 300 mA
Switching hysteresis <15% (Sr)
Repeat accuracy <5% (Sr)
Protection level IP55
Working temperature 0 °C to +55 °C
Connection method Ø6.5 mm 2 m PVC cable, 3x0.33 mm² (3-wire) / 4x0.33 mm² (4-wire)
Housing 50 x 50 x 18 mm, ABS
Indicator Red LED
Weight About 97 g + 10 g reflective board
Certification CE, RoHS

Dimensions

DK-GF18 retro-reflective dimension drawing with reflective board
Sensor outline (50 x 50 x 18 mm) and the supplied reflective board (61 x 50 mm).
DK-GF18 sensor with 2 m PVC cable and reflective board
Sensor with 2 m PVC cable; a reflective board is supplied with retro-reflective versions and a transmitter / receiver pair with through-beam versions.

Wiring

DK-GF18 DC 3-wire and 4-wire NPN PNP NO NC wiring diagrams
All six DC 3-wire / 4-wire NPN and PNP NO, NC and NO+NC connections used by this group.
Wire colour Function
Brown (1) +10-30 V DC
Blue (3) 0 V
Black (2 / 4) Switched output to load
White (2) Second switched output on 4-wire models

Confirm the wiring against the label of the unit received before energising. Do not connect the output to a load exceeding the rated current.

Request a quote for this specification group

Tell us the exact part number from the model table, the target object and distance, your supply voltage, and the quantity. Our engineers will confirm the configuration and send a quotation. This is a general-purpose photoelectric sensor for object detection; it is not a safety-rated device and must not be used for personnel protection.

Get a Quote