DK-GF18 Series AC/DC Relay Output Diffuse Reflection Sensors
- Model
- DK-GF18 Series / AC-DC Relay Diffuse (2 models)
Item specifics
- Series
- DK-GF18 Series
- Specification group
- AC/DC 5-wire Relay Diffuse Reflection
- Part numbers in group
- 2
- Sensing distance
- 80-500 / 100-1500 mm adjustable
- Light source
- 850 nm infrared
- Operating voltage
- 12-240 V DC / 24-240 V AC
- Output options
- 5-wire relay, NO + NC
- Maximum load current
- 3 A / 30 V AC, 1 A / 220 V AC
- Protection level
- IP55
- Housing
- 50 x 50 x 18 mm, ABS
- Response time
- 20 ms
- Connection
- Ø6.5 mm 2 m PVC cable
- Weight
- About 95 g
- Certification
- CE, RoHS
Review
Description
DADISICK · DK-GF18 Series · Group D AC/DC wide-voltage diffuse reflection sensors with a built-in 5-wire relay output that drives loads directly at 3 A / 30 V AC or 1 A / 220 V AC. 2 orderable part numbers for 80-500 mm and 100-1500 mm adjustable sensing distances. This group contains 2 orderable part number(s). Choose the output type and sensing distance you need, then quote the exact part number from the table below. Output codes: NO / NC / NS = NPN NO / NC / NO+NC; PO / PC / PS = PNP NO / NC / NO+NC; J = relay output. 3-wire models use one switched output, 4-wire models provide NO + NC, and relay models provide NO + NC contacts. Confirm the wiring against the label of the unit received before energising. Do not connect the output to a load exceeding the rated current. Tell us the exact part number from the model table, the target object and distance, your supply voltage, and the quantity. Our engineers will confirm the configuration and send a quotation. This is a general-purpose photoelectric sensor for object detection; it is not a safety-rated device and must not be used for personnel protection.AC/DC Relay Output Diffuse Reflection Sensors
Get a Quote
Orderable models in this group
Part number
Output
Wires
Sensing distance
DK-GF18-50J-ZAB
Relay output, NO + NC
5-wire
80-500 mm
DK-GF18-150J-ZAB
Relay output, NO + NC
5-wire
100-1500 mm
Technical parameters
Parameter
Value
Sensing distance
80-500 mm / 100-1500 mm, adjustable
Light source
850 nm infrared light
Standard detection object
200 x 200 mm white cardboard
Output options
AC/DC 5-wire relay output, NO + NC
Operating voltage
12-240 V DC / 24-240 V AC
No-load current
≤20 mA
Maximum load current
3 A / 30 V AC, 1 A / 220 V AC
Voltage drop
≤2.5 V
Switching frequency
10 Hz
Response time
20 ms
Switching hysteresis
<15% (Sr)
Repeat accuracy
<5% (Sr)
Protection level
IP55
Working temperature
0 °C to +55 °C
Connection method
Ø6.5 mm 2 m PVC cable, 3x0.33 mm²
Housing
50 x 50 x 18 mm, ABS
Indicator
Red LED
Weight
About 95 g
Certification
CE, RoHS
Dimensions
Wiring
Wire colour
Function
Brown
+12-240 V DC / 24-240 V AC
Blue
0 V
Black
NO contact
Gray
COM terminal
White
NC contact
Request a quote for this specification group